When restarting the Foglight Management Server or Foglight Agent Manager multiple alarm emails are sent. Is it possible to prevent the multiple alarms?
WORKAROUND 1
From the Manage Rules dashboard edit the Agent Health State rule and alter the rule behavior to wait for a longer time before alarms fire; for example:
WORKAROUND 2
Configure a global blackout, for more information refer to How to blackout all of Foglight (4213624).
WORKAROUND 3
Configure a rule blackout for Agent Health State.
WORKAROUND 4
Manually deactivate agents before restarting the FglAM.
WORKAROUND 5
Enable a topology object blackout for the Agent topology using the command line:
[FMS_HOME]/bin/fglcmd -cmd topology:blackoutobject -query '!Agent' -schedulename SCHEDULE_NAME -inheritable
[FMS_HOME]/bin/fglcmd -cmd topology:blackoutobject -query '!Agent' -clear
The SCHEDULE_NAME can be obtained from the schedules dashboard or using [FMS_HOME]/bin/fglcmd -cmd schedule:list
from the command line.
STATUS
Enhancement request FOG-6034 has been submitted to development for consideration in a future release of the Foglight Management Server.