For more information about installing and configuring the Agent Manager, see the Foglight Agent Manager Installation Guide.
The management log reports on the copying of the cartridges.
ERROR [UDP mcast receiver] org.jgroups.protocols.UDP - message does not have a UDP header
ERROR [UDP mcast receiver] org.jgroups.protocols.UDP - discarded message from different group
If you see this type of message, change the cluster multicast port of the servers that are reporting the error. In addition, if you plan to have multiple High Availability (HA) partitions on the same subnet, configure a different cluster multicast port for each HA partition. See Configuring the cluster multicast port used in HA mode for instructions.
Each Management Server in an HA cluster checks its own internal health.monitor.port to try and determine the server health. If this check fails, the server is automatically restarted. The HA Health Check Monitor does not use HTTPS, so when the Management Server is configured to use HTTPS/SSL, the port health check fails and the server is restarted.
To prevent this issue, configure the Health Check URL in the restart_monitor.config to use HTTP and port 8080.
By default, the URL is:
health.check.url=”https://localhost:8443/foglight-sl/HealthCheck”;
Specify HTTP as the transport protocol, and define the actual Management Server host name and port 8080. For example:
health.check.url=”http://hostname:8080/foglight-sl/HealthCheck”;
Ensure that the URL is updated on each server in the cluster.