WORKAROUND
Steps to apply (helpful screenshots also included)
1. Logon to FMS console with user that has "Cartridge Developer" role
2. Navigate to Configuration > Defintions: and select "Databases"
3. Find the view "Databases Explorer" and edit
4. Move to "Context" tab and create an input in the "Additional" section
a. Name it "groupInstances-explorer"
b. Select binding > List
c. Check all three "Merge Lists", "Remove Nulls", "Remove Duplicates"
d. Add 5 items to the list
1) gvNodes
2) ASMInstances: Path -> clustersGlobalView
3) CRS: Path -> clustersGlobalView
4) ExadataInstances: Path -> clustersGlobalView
5) DataGuardInstances: Path -> clustersGlobalView
e. Move the "groupInstancesExplorer" node above "values"
5. Edit the input "values" and set "groupInstancesExplorer" as the first parameter instead of gvNodes
6. Save the View.
STATUS
This issue has been logged as defect FOG-9046 and has been fixed in the 7.3.0.10 and higher Global View cartridges.