A lot of dashboards are missing after Foglight upgrade and some dashboards are showing the following error:
"For the value "true", no view is set"
Even all Administration dashboards disappeared.
After the upgrade the Foglight restart failed due to an old Intelliprofile cartridge which is not compatible with the higher core cartridges.
Intelliprofile cartridge 5.6.5.8 was still enabled and stopped other cartridges to load properly.
To fix the issue, please enable the core-administration cartridge. As the Cartridge Inventory dashboard is not available please use the fglcmd command line tool as described here.
Once the Administration dashboards are back, open the Cartridge Inventory dashboard. Find the old Intelliprofile cartridge 5.6.5.8 and uninstall it. Afterwards enable/install the most current Intelliprofile cartridge.
Finally enable all cartridges (Core + Installed ones) which are still disabled.