Process Availability rule triggers false alarms for process on Linux host. Process is listed in "ps" output.
说明
The Process Availability rule is triggering alarms for a process that was recently added to the Process Availability Config list.
The value used in the Process Name column (Foglight 5.7.5.7: Foglight Daemon) is listed in the "ps" output on the host.
原因
The value in the "Process Name" field (Foglight 5.7.5.7: Foglight Daemon) of the Process Availability Config list does not match the "Process Name" value (fms) listed under the Monitored processes table in the Infrastructure Processes dashboard.
解决办法
Change the value in the "Process Name" field of the Process Availability Config list so that it matches the process name reported under the Monitored Processes table in the Infrastructure Processes dashboard.