Provide details of the SNMP manager used by the Spotlight Diagnostic Server (to fulfill on Configure | Alarm Actions | Alarm Action | Send SNMP Trap).
Requirements
A textual representation of the information sent by the Spotlight Diagnostic Server to the SNMP manager is defined in a MIB file. Ensure this MIB file is accessible to your SNMP manager. The MIB file is in the Spotlight Diagnostic Server installation folder, Agent\bin\DiagnosticServer.mib.
Open this screen from the Spotlight Client
Click Configure | Diagnostic server.
Select the Diagnostic Server
For federated Spotlight Diagnostic Server (Federate Diagnostic Servers) you will be prompted to select the Spotlight Diagnostic Server to configure. Each Spotlight Diagnostic Server is independently configured for SNMP.
Fill in the details
Field | Description |
---|---|
SNMP Manager Address |
Enter the host name or IP address of the SNMP manager. The SNMP trap is sent to this address. Enter localhost to send the SNMP trap to the same computer as the Spotlight Diagnostic Server. |
Port |
The SNMP manager is running on this port. The default value is 162. This is the standard setting. The port number must be correct for the Spotlight Diagnostic Server to send SNMP traps to the SNMP manager. It is critical that the port number is set correctly and it is your responsibility to ensure it is correct. Spotlight cannot detect the port number used by the SNMP manager so Spotlight reports no error if the port number is incorrect. |
Version |
Select one of the SNMP versions: SNMPv1, SNMPv2C, SNMPv3. |
Community |
Community is applicable to SNMPv1 and SNMPv2C. The default community value is Public. This is the conventional factory default setting for most SNMP equipment. You can change the community value in Spotlight. Ensure the SNMP manager is configured to recognize the community value set in the Spotlight Diagnostic Server. |
When version SNMPv3 is selected then enter configuration specifications for username/password authentication and/or data encryption.
Option | Description |
---|---|
USM User |
Your username to the SNMP service. |
Authentication Protocol |
Select the appropriate authentication protocol
|
Authentication Password |
Enter the authentication password if applicable. |
Privacy Protocol |
Select the appropriate privacy protocol
|
Privacy Password |
Enter the privacy password if applicable. |
Click Send Test Trap to verify the Spotlight configuration. The test trap checks for basic configuration errors. You should verify the test trap was successfully received by the SNMP manager.
© 2022 Quest Software Inc. ALL RIGHTS RESERVED. Feedback Terms of Use Privacy