Chat now with support
Chat with Support

KACE Systems Deployment Appliance 8.0 Common Documents - Administrator Guide

About the KACE Systems Deployment Appliance Getting started Using the Dashboard Configuring the appliance Setting up user accounts and user authentication Configuring security settings Preparing for deployment Managing device inventory Using labels Creating a Windows or Linux Boot Environment Managing drivers Capturing images Capturing user states Creating scripted installations Creating a task sequence Automating deployments Performing manual deployments Managing custom deployments Imaging Mac devices About the Remote Site Appliance Importing and exporting appliance components Managing disk space Troubleshooting appliance issues Updating appliance software Glossary About us Legal notices

Troubleshooting the Boot Manager

Troubleshooting the Boot Manager

You can change the Boot Manager interface for devices that do not support the integrated graphics required to load the KBE and configure how long the Boot Manager displays on target devices. You can also set the duration that the appliance waits for the DHCP server to respond, and test device network connectivity.

Test whether a target device can network boot

Test whether a target device can network boot

If the Network Interface Card (NIC) on the target device supports network booting, you can test whether a target device can boot from the appliance.

The target device successfully boots.

Set the Boot Manager timeout

Set the Boot Manager timeout

When you network boot a device in to the KACE Boot Environment (KBE), you can specify how long the Boot Manager displays on a target device.

Typically, in a test environment where you are setting up and troubleshooting devices, you can increase the timeout. In a production environment; however, decreasing the timeout to a few seconds should discourage users from attempting to interrupt the boot sequence.

1.
On the left navigation pane, click Settings to display the Control Panel, then click General Settings to display the General Settings page.
2.
In Boot Manager Timeout, enter the duration in seconds.
3.
Click Save.

The Boot Manager timeout for all PXE boots from the appliance is changed.

Select the local hard disk boot method

Select the local hard disk boot method

When you boot a device from the hard drive, you can specify how you want the device to boot.

 

Both local and chain boot methods are available, but the chain boot method is recommended.

1.
On the left navigation pane, click Settings to display the Control Panel, then click General Settings to display the General Settings page.
2.
Click Local Hard Disk Boot Method BIOS, and select the boot method for BIOS devices.
Chain Boot: Select this option if you want to use iPXE to chain-boot the device to its hard drive.
Local Boot: Select this option if you want to use built-in iPXE commands to do a boot from the hard drive.
3.
Click Local Hard Disk Boot Method UEFI, and select the boot method for UEFI devices.
Chain Boot: Select this option if you want to run a UEFI script to load the Windows UEFI boot manager.
Local Boot: Select this option if you want to use built-in iPXE commands to do a boot from the hard drive.
4.
Click Save.
Related Documents

The document was helpful.

Select Rating

I easily found the information I needed.

Select Rating