When I attempt to set the parameter SP_OCT_ONELINE_DEBUG to point to more than one object by specifying their OBJECT_ID, it errors out as below (where I have attempted to set them to the object ids 1000 and 2000 respectively) and instead tries to be helpful by providing the syntax for the command:
sp_ctrl (alvsupl14:9241)> set param SP_OCT_ONELINE_DEBUG 1000, 2000
Usage: set param name value [on host]
Or: set param name [queue quename] [to host] value [on host]
Or: set param name [from host] [queue quename] value [on host]
Or: set param name [queue quename] [for datasrc-datadst] value [on host]
Or: set param name [for datasrc] value [on host]
The object IDs need to be separated with comma only with no space before or after the comma.
Though the requirement is not specifically documented in SharePlex Reference Guide, if multiple object IDs need to be specified, they should be separated with comma only with no space after the comma as shown below:
sp_ctrl (alvsupl14:9241)> set param SP_OCT_ONELINE_DEBUG 1000,2000