After successfully performing a Bare Metal Recovery restore of a Windows system to an alternate server, the new server fails to boot.
Shortly after displaying the Windows logo, the machine blue screens, and if configured too, automatically attempts a reboot. The blue screen error is "STOP 0x0000007B INACCESSABLE_BOOT_DEVICE"
Enter the new server's BIOS, check the hard disk mode and compare to the original server. There are multiple settings depending on the motherboard, from RAID, AHCI or IDE. Ensure that this is the same as the original server and reboot.