When attaching FC attached SL500 library using the add library option a “Library Geometry Unavailable” warning popup appears.
Library was setup with multiple paths which is not supported with netvault. Path was reduced to 1 path but the “Library Geometry Unavailable” warning popup still appears.
We verified that the tape library magazines that contain the tapes were inserted in the library
Using Linux mtx commands we proved that the library was not responding to inventory or status commands as seen below:
# mtx -f /dev/sg334 inventory
mtx:inventory failed
# mtx -f /dev/sg334 status
mtx: Request Sense: 70 00 02 00 00 00 00 0C 00 00 00 00 04 0C 00 00 00 00 00 00
READ ELEMENT STATUS Command Failed