Shareplex could not be started as sp_cop causes a segmentaion fault at start up.
Shareplex is using incorrect library links.There cannot be two or more intances of shareplex with the same version and different patch level on one server.
RESOLUTION 1:
1.Ensure that shareplex is started from correct product directory
2.Point the library links to the corerct Shareplex version product directory
3. Restart sp_cop.
RESOLUTION 2:
Have instances with same version of shareplex at same patch level on one server.
There cannot be two or more intances of shareplex with the same version and different patch level on one server.
For example
There cannot be 5.3.2 and 5.3.4 on one machine or 5.1.6 and 5.1.7 on one machine
The libaries in var/adm/.splex/v_5.3/lib* will point to the latest 5.3 installation libraries, it cannot point to both 5.3.4 and 5.3.2 at the same time. Similarly var/adm/.splex/v_5.1/lib* will point to the latest 5.1 installation, it cannot point to both 5.1.6 and 5.1.7 at the same time.