When a monitored database server is shut down, the DBSS - Usability Connection Availability and DBSS - Usability OS Connection Availability alarms might not trigger for 15 minutes or more, even though other collection alarms (like “Collection Status”) appear within 1–2 minutes.
| Time | Event |
| 17:31:11 | DB Connect Availability = TRUE |
| 17:31:17 | OS Connect Availability = TRUE |
| 17:34:41 | VM powered off (host becomes unreachable) |
| 17:34:41–17:54:59 | Multiple collections queued/hung due to network timeouts, no usable checks finish |
| 17:54:59 | Usability collection finally starts |
| 17:58:29 | Usability collection fails after 3.5 min, alarm triggers |
However:
| Setitng Name | Recommended | Legacy/Slow |
| The amount of time to wait for network activity before timing out (seconds) | 30 seconds to 60 seconds | 900 seconds (15 minutes) |
| Connection Timeout (milliseconds) (under OS-Monitored Connection Profile) | 10 seconds to 30 seconds | 120 seconds |
| DB Connection Timeout (milliseconds) | 10 seconds to 30 seconds | 60 seconds |
| Usability Collection Timeout | 60 seconds | 60 seconds |
| Setitng Name | Recommended | Legacy/Slow |
| DB Read timeout while reading from the socket (milliseconds) | 30 seconds to 60 seconds | 900 seconds (15 minutes) |
| Connection Timeout (milliseconds) (under OS-Monitored Connection Profile) | 10 seconds to 30 seconds | 120 seconds |
| DB Connection Timeout (milliseconds) | 10 seconds to 30 seconds | 60 seconds |
| Usability Collection Timeout | 60 seconds | 60 seconds |
Why do other alarms fire sooner?