KACE SMA supports two types of Organization Filters:
- Data Filters - Assign devices to organizations based on inventory data and search criteria.
- LDAP Filters - Assign devices to organizations based on LDAP or Active Directory queries.
Automatically Assign New Devices to an Organization
- Create the target organization if it does not already exist.
- Create an Organization Filter that identifies the devices to be assigned.
- Associate the Organization Filter with the desired organization.
- Allow the device to complete an inventory cycle or perform a force inventory.
- Verify that the device has been assigned to the correct organization.
Create an Organization Filter
- Log in to the KACE SMA Administrator Console.
- Navigate to SystemUI | Organizations | Filters.
- From the Choose Action menu, select either New Data Filter or New LDAP Filter.
- Provide a meaningful name for the filter.
- Configure the filter criteria that devices must meet to be assigned to the organization.
- Assign an Order (Data Filter) or Evaluation Order (LDAP Filter).
- Select the Enabled check box.
- Click Save.
Associate the Filter with an Organization
- Log in to the KACE SMA Administrator Console.
- Navigate to SystemUI | Organizations | Organizations.
- Select the organization that will receive the devices.
- Open the Filters section.
- Select the desired Organization Filter or Filters.
- Click Save.
Test an Organization Filter
Organization Filters can be tested to verify that they identify the expected devices before relying on them for automatic device assignment.
- Navigate to SystemUI | Organizations | Devices.
- Click the Test Organization Filter tab.
- Select the desired filter.
- Click Test.
- Review the results and adjust the filter if necessary.
Notes and Limitations
- Organization Filters cannot be assigned to the Default organization.
- Devices that do not match any configured Organization Filter are assigned to the Default organization.
- Devices assigned to the Default organization can be manually moved to another organization if needed.
- The same Organization Filter cannot be assigned to multiple organizations.
- Filter Order and Evaluation Order determine the sequence in which filters are processed.
- Data Filters support only AND logic within a single filter.
- To achieve OR logic, create multiple Data Filters and assign them to the same organization.
- Organization Filters must be enabled before they can be applied.
Move Existing Devices to Another Organization
If a device is already assigned to the wrong organization, it can be manually reassigned.
- Navigate to SystemUI | Organizations | Devices.
- Select the desired device or devices.
- Choose Choose Action | Assign.
- Select the destination organization.
- Apply the change.
After moving a device, perform a force inventory or allow the next scheduled inventory cycle to complete. If duplicate or disconnected records remain in the previous organization, verify that the device is successfully reporting to the new organization before removing obsolete records.
Troubleshooting
- Review filter criteria if devices are not being assigned to the expected organization.
- Use the Test Organization Filter feature to validate filter behavior.
- Confirm that filters are enabled and associated with the intended organization.
- Verify the configured Order or Evaluation Order if multiple filters are present.
- Force an inventory cycle after creating or modifying filters to confirm assignment behavior.
Additional Resources