In vFoglight Storage, My Brocade switches are all gray and in the Data Collection Setup menu the durations for performance and topology are hours. I am collecting from over 100 switches.
This is a known defect in vFoglight Storage caused by a bug referenced by Quest Tracking ID 1216. The SMIs collector is taking too long to gather the information and this delay is causing the collection schedule to be missed.
Workaround 1:
If you change to collection schedule to be longer than the time it takes to get the performance information, the switches will have performance data available.
Defect request 1216 has been submitted to Development for a fix in a future release. Please check the release notes of latest software to determine which bug fixes have been included in this release.
The latest version of vFoglight Storage can be downloaded at:
vFoglight Storage version 1.6.0