The following errors are seen in the event log
10/17/06 14:18 Warning: A portion of the redo log could not be parsed [sp_ocap/80652]
10/17/06 14:18 Notice: Begin record skip at seqno=39259 offset=0 rc=5 [sp_ocap/80652]
10/17/06 14:18 Notice: OlogparGetNextRecord: OlogReadRec return BAD_LOG...retry (0 of 5). [sp_ocap/80652]
Redo logs were on raw file system
sp_ctrl>stop capture
sp_ctrl>set param SP_OCT_REDO_RAW_OFFSET 0
sp_ctrl>start capture
SP_OCT_REDO_RAW_OFFSET description:
This parameter tells the Capture process how many bytes to skip when it reads a redo log or data file that is located on a raw device. These bytes need to be skipped on certain platforms because they are reserved for the operating system's use. This parameter should be kept to the default setting of -1, which tells Capture to use the default value that is programmed for the platform.
Setting the parameter to 0 for AIX means that the default value used is not true and that no offset should be used when reading the redo logs. The parameter below is a workaround in case the offset has changed.