Sample SCSI errors shown under different conditions.
From media loaded into tape drive:
SCSI :3776 14 0 103302 CMD TEST UNIT READY [ 00 00 00 00 00 00 ]
SCSI :3776 16 0 103302 CMD STATUS 'CHECK CONDITION' [2]
SCSI :3776 17 0 103302 CMD SENSE KEY 'NOT READY ' [2] - ASC 3a ASCQ 00
SCSI :3776 18 0 103302 CMD SENSE INFO 'MEDIUM NOT PRESENT'
SCSI :3776 20 0 103302 CMD RETURN VALUE 2
TAPESCSI:3776 41 0 103302 No Media in device
TAPESCSI:3776 114 0 103302 Do A Load Media (END)
TAPESCSI:3776 45 0 103302 Load Media (END)
DEVMGR :3776 40 1 103302 Failed to load device
From media moved from tape drive to slot:
CHGSCSI 24 0 101145 CMD STATUS 'CHECK CONDITION' [2]
CHGSCSI 25 0 101145 CMD SENSE KEY 'ILLEGAL REQUEST' [5] - ASC 3b ASCQ 0e
CHGSCSI 74 0 101145 CMD SENSE INFO 'MEDIUM SOURCE ELEMENT EMPTY '
CHGSCSI 107 0 101145 0x2 = ChgScsiCmd(0x807e860)
CHGSCSI 17 0 101145 Got sense ILLEGAL REQUEST ASC 3b0e from MoveMedia
From media moved from slot to tape drive:
CHGSCSI 24 0 115422 CMD STATUS 'CHECK CONDITION' [2]
CHGSCSI 25 0 115422 CMD SENSE KEY 'ILLEGAL REQUEST' [5] - ASC 3b ASCQ 0d
CHGSCSI 74 0 115422 CMD SENSE INFO 'MEDIUM DESTINATION ELEMENT FULL '
CHGSCSI 107 0 115422 0x2 = ChgScsiCmd(0x807e860)
CHGSCSI 17 0 115422 Got sense ILLEGAL REQUEST ASC 3b0d from MoveMedia