When attempting to use an HP Lefthand storage device as a repository you may receive the above error when attempting to backup.
.Error Message: 2654 - can't read vix:{xxxxxxxxxxxxxxxxx}:902:[DatastoreName] Vmname/vmname.vmdk:moref=vm-12300:snapshot-32013:2 [at io_size:125]
vmkernel: 17:01:30:38.273 cpu6:4102)NMP: nmp_CompleteCommandForPath: Command 0x2a (0x41027fa06e40) to NMP device "naa.6000eb3b1371b311000000000000004f" failed on physical path "vmhba32:C1:T2:L0" H:0x0 D:0x2 P:0x0 Valid sense data: 0x3 0x0 0x0. The codes translate to: Host = H:0x0 = OK Device = D:0x2 = CHECK CONDITION Sense Key = 0x3 = MEDIUM ERROR Additional Sense Code/ASC Qualifier = 0x0/0x0 = NO ADDITIONAL SENSE DATA · vmkernel: 17:01:30:39.387 cpu6:4102)ScsiDeviceIO: 1672: Command 0x2a to device "naa.6000eb3b1371b311000000000000004f" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x9 0x4 0x2 The codes translate to: Host = H:0x0 = OK Device = D:0x2 = CHECK CONDITION Sense Key = 0x3 = VENDOR SPECIFIC Additional Sense Code/ASC Qualifier = 0x4/0x2 = LOGICAL UNIT NOT READY - INITIALIZATION COMMAND REQUIRED
When attempting to use an HP Lefthand storage device as a repository you may receive the above error when attempting to backup.
If the HP LeftHand DSM for MPIO is installed on a Windows host that is presented the same LUNs as ESX, this can cause LUN accessibility issues for ESX hosts. This issue occurs due to the unique LUN locking ability of the DSM for MPIO.
The storage stack for ESX will use SCSI-2 Reserve/Release commands or the Atomic Test & Set (ATS) capability of VAAI to lock a LUN, neither of which works with the HP Lefthand DSM for MPIO. HP recommends against installing the HP LeftHand DSM for MPIO on any host that has visibility to ESX LUNs.