When loading a unisys.mib file, the FMS produces an error.
error: INTERNAL ERROR: value identifier 'COMS' doesn't start with a lowercase character on line -1
We see in unisys.mib that most of the object identifiers start with lower case letters except the COMSxxx definitions.
Line 5060: eServerStatusSummary OBJECT IDENTIFIER
Line 5149: eServerMCPGroup OBJECT IDENTIFIER ::= { eServerProcResource 3 }
Line 5187: esMCP481Group OBJECT IDENTIFIER ::= {eServerMCPGroup 5 }
Line 5758: mcp-hr-ext OBJECT IDENTIFIER ::= {uni-processors 5}
Line 5870: COMSMonitor OBJECT IDENTIFIER ::= {uni-processors 6}
Line 5872: COMSMonitorConfigGroup OBJECT IDENTIFIER ::= { COMSMonitor 1 }
Line 5874: COMSMonitorGeneralConfig OBJECT IDENTIFIER ::=
Line 5992: COMSMonitorWindowConfig OBJECT IDENTIFIER ::=
Line 6033: COMSMonitorProgramConfig OBJECT IDENTIFIER ::=
Line 6074: COMSMonitorStatusGroup OBJECT IDENTIFIER ::= { COMSMonitor 2 }
Line 6076: COMSMonitorSummaryStatus OBJECT IDENTIFIER ::=
Line 6202: COMSMonitorGeneralStatus OBJECT IDENTIFIER ::=