Cartridge for SQL Server Unavailable Fatal alarm took over an hour to fire.
The Database_Summary collection is responsible for providing the metrics for evaluation to trigger the alarm when applicable. The offline collection interval is set @ 3600 seconds by default in which could cause the alert to delay firing, notifying when the database is not available. You can consider increasing the collection offline default time from 3600 seconds to collect more frequent.